Homeowners can have the added assurance that their basements will be protected from flooding, even in the most extreme circumstances. The Ion Technologies line of battery backup pump systems can be equipped to operate with heavy duty Power Plus AGM Batteries, which perform better and can last twice as long as standard batteries. Our high capacity backup pump systems can provide the most amount of gallons pumped-per-minute, providing ultimate basement flood protection under the most extreme circumstances. Our sump pumps are built with higher-grade materials to help protect against normal wear and tear, resulting in prolonged pump life.
Battery backup sump pump systems are a necessary add-on for any basement to help protect it from flooding. A basement with a primary pump by itself is more likely to eventually flood. A sump pump can stop working due to a mechanical failure caused by normal wear and tear, a float switch gone bad or due to the loss of power. Power outages are most likely to occur during a heavy rainstorm, which is obviously the worst time you’d want to lose your power and the functionality of your sump pump.
Battery Backup Inverter Comparion Chart
Ion Sumpro
Ion 55ACi
Ion 35 ACi
Ion 30 ACi
Compatible Sump Pumps
BA33 1/3 HP Pumps
BA50 1/2 HP Pumps
BA75 3/4 HP Pump
WC33 1/3 HP Pumps
BA33 1/3 HP Pumps
BA50 1/2 HP Pumps
WC33 1/3 HP Pumps
BA33 1/3 HP Pumps
WC33 1/3 HP Pumps
Number of Sump Pumps That can run simataneously
BA33 1/3 HP Pumps - 2
BA50 1/2 HP Pumps - 2
BA75 3/4 HP Pumps - 1
WC33 1/3 HP Pumps - 2
BA33 1/3 HP Pumps - 2
BA50 1/2 HP Pumps - 1
WC33 1/3 HP Pumps - 1
BA33 1/3 HP Pumps - 1
WC33 1/3 HP Pumps - 1
Number of Batteries
2
2
1 or 2 (with battery addon kit)
1 or 2 (with battery addon kit)
Inverter Specifications
A.C. Lower Voltage Limit 98 VAC ± 5V
Output Voltage with Full Load 85-135V ± 10V
Maximum Output Current 12 FLA
Battery Lower Voltage Limit 18.5V ± 0.3V
Main Output Frequency 60 Hz
Overload 125 ± 3% (With Auto
Reset Function)
Alarm Contact RJ11 Connection,
Normally Closed Dry
Contact
Alternative DC Inputs 24VDC, 20A max
A.C. Lower Voltage Limit 90 VAC ± 5V
Output Voltage with Full Load 120V/110 ± 10V
Battery Lower Voltage Limit 21 VOC ± 0.2V
Maximum Output Current 9 FLA
Battery Input 24 VDC
Battery Charger Boost Voltage 13.7 ± 0.2V (Per Battery)
Overload 130 ± 3% (With Auto Reset Function
Mains A.C. Lower Voltage Limit - 90 VAC ± 5V
Output Voltage with Full Load - 110 - 120V ± 10 V
Maximum Output Power - 5.5 FLA
Battery Lower Voltage Limit - 10.5 VOC ± 0.2 V
Output Frequency Main Output Frequency: Same as Input
DC Input - 12 VDC
Battery Charger Boost Voltage - 13.7 ± 0.2 V
Overload - 130% ± 3% (With Auto Reset Function)
Mains A.C. Lower Voltage Limit - 90 VAC ± 5V
Output Voltage with Full Load - 110 - 120V ± 10 V
Maximum Output Power - 5.5 FLA
Battery Lower Voltage Limit - 10.5 VOC ± 0.2 V
Output Frequency Main Output Frequency: Same as Input